ABB launches high-performance breaker line

Houston, Texas—ABB, a power and automation technology group, announced it has launched a high-voltage, high-performance 72.5 kV dead-tank breaker line, serving ratings as  low as 15 kV and up to 72.5 kV for power transmission and distribution systems.

ABB began initial activity for the type 72PM40-30B dead tank gas circuit breaker in October 2011.  The original 72PM was designed in the mid 1980s and will continue in production until its eventual phase-out in 2013.  The new “B model” breaker is designed to meet and exceed the modern standards that harmonize between the IEEE and IEC global standards, and is based on the best-in-class features of over 9,000 units of type PM history and over 2,000 units of PASS.

To bring this compact yet high-performance breaker to life, a joint development team in Italy, Switzerland, Sweden and the US began developing a product for maximum performance while optimizing the design in order to compete in what remains the largest global market for this type of product. In conjunction with this launch, ABB also released the upgraded PASS M00 hybrid module with the same ratings as the dead-tank breaker. The PASS (Plug and Switch System) integrates additional functionality of gas insulated disconnectors, PT’s and cable plug-ins as options.  The PASS remains the hallmark of hybrids globally and continues to gain acceptance due to the space savings and high availability ratings.

As a result, the 72PM40-30B has exceeded expectations and has completed testing in independent laboratories (CESI, KEMA) to validate the 40 kA, 3 cycle design.  Since the designs core uses the proven CSB-0 145 kV class interrupter, the breaker performed beyond expected limits, making it suitable for high X/R ratio applications where system conditions may be beyond standards. The mechanism chosen was the popular BLK-222 spring-spring drive with over 35,000 installations on LTB, DTB and PASS worldwide.

The breaker is rated for the maximum applications of M2 (10,000 operations mechanical endurance), C2 (capacitor switching endurance), cap switching factor of 1.4 (highest level in standards) and first-pole-to-clear factor (defines most severe TRV requirements) of 1.5.  The design is made so that it fits the footprint of ABB’s current 72PM and easily replaces other brands.

Production began in ABB’s modern San Luis Potosi facility this past February.  The breaker will then be localized in ABB’s Mt. Pleasant, Pennsylvania facility later this year for dual manufacturing locations that will give ABB capacity equal or greater than our competition at these voltage levels.

For more information about ABB or other breaker lines, click here to go to Utility Products' Buyers Guide.



Did You Like this Article? Get All the Energy Industry News Delivered to Your Inbox

Subscribe to an email newsletter today at no cost and receive the latest news and information.

 Subscribe Now

Whitepapers

Logistics Risk Management in the Transformer Industry

Transformers often are shipped thousands of miles, involving multiple handoffs,and more than a do...

Secrets of Barco UniSee Mount Revealed

Last year Barco introduced UniSee, a revolutionary large-scale visualization platform designed to...

The Time is Right for Optimum Reliability: Capital-Intensive Industries and Asset Performance Management

Imagine a plant that is no longer at risk of a random shutdown. Imagine not worrying about losing...

Going Digital: The New Normal in Oil & Gas

In this whitepaper you will learn how Keystone Engineering, ONGC, and Saipem are using software t...